<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.pranavfiresafety.com/blogs/fire-safety/feed" rel="self" type="application/rss+xml"/><title>Best Fire Extinguisher Dealer In Ahmedabad Gujarat. - Blogs , Fire Safety</title><description>Best Fire Extinguisher Dealer In Ahmedabad Gujarat. - Blogs , Fire Safety</description><link>https://www.pranavfiresafety.com/blogs/fire-safety</link><lastBuildDate>Sun, 15 Sep 2024 03:51:45 -0700</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[GUIDE FOR INSTALLATION, OPERATION, INSPECTION, MAINTENANCE, &amp; RECHARGING OF THE FIRE EXTINGUISHERS (STORED PRESSURE TYPE)]]></title><link>https://www.pranavfiresafety.com/blogs/post/GUIDE-FOR-INSTALLATION-OPERATION-INSPECTION-MAINTENANCE-RECHARGING-OF-THE-FIRE-EXTINGUISHERS-STORED-PRESSURE-TYPE</link><description><![CDATA[ABOUT : Fire extinguishers must be serviced in order to operate properly between the time intervals stipulated and also to avoid a potential hazard to ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_SAcG8YtAQNm7CgUsgqy2Zw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_oRNL0NdyQdioBeCay4YBjQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_e4B1H7rVQt2fwfem8-IeXQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_7lyqqpU7TI6wOx7yeVnBOg" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align- " data-editor="true"><div><p><font color="#ff0000" size="4"><b>ABOUT :</b></font></p><p><font color="#000000" size="4">Fire extinguishers must be serviced in order to operate properly between the time intervals stipulated and also to avoid a potential hazard to person in its vicinity or to those who operate or recharge the extinguishers. This guide lays down the recommendation for the intended Installation, Operation, Inspection, Maintenance, and Recharging of the extinguisher.<b></b></font></p><p><font color="#000000" size="4"><b><br></b></font></p><p><font color="#ff0000" size="4"><b>SUITABILITY OF PORTABLE FIRE EXTINGUISHER</b></font></p><p><font color="#000000" size="3">Fire Extinguisher suitability is based on the extinguishing media. Refer following tabel shows suitability based on type of media :</font></p><p><font color="#000000" size="4"><b><br></b></font></p></div></div>
</div><div data-element-id="elm_ZyAuhmovQR2t0QH3KPmpww" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align- " data-editor="true"><div><div style="overflow:auto;"><table style="float:left;width:100%;"><tbody><tr><th width="33%"><font size="4"><b>Sr No. </b></font></th><th width="33%"><font size="4"><b> Type Of Media</b></font></th><th width="33%"><font size="4"><b> Suitability Of Classes</b></font></th></tr><tr style="text-align:left;vertical-align:top;height:10%;"><td style="text-align:left;vertical-align:top;" width="1%"> 1</td><td width="33%"> Mono - ammonium Phosphate</td><td width="33%"> A, B &amp; C</td></tr><tr style="text-align:left;vertical-align:top;height:5%;"><td width="33%"> 2</td><td width="33%"> SBC</td><td style="text-align:left;vertical-align:top;" width="20%"> B &amp; C</td></tr><tr><td width="33%"> 3</td><td width="33%"> Water with Additive&nbsp;</td><td width="33%"> A</td></tr><tr style="text-align:left;vertical-align:top;height:10%;"><td width="33%"> 4</td><td width="33%"> Mechanical Foam</td><td width="33%"> A &amp; B</td></tr></tbody></table></div></div></div>
</div><div data-element-id="elm_OfxkbA0cRcKMfMcgAEIOMA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align- " data-editor="true"><div><p><font color="#ff0000" size="4"><b>INSTALLATION&nbsp;</b></font></p><p></p><ul><li>Inspect the Extinguisher for it's completeness of supply and check with packing and dispatch documents before installation</li><li>Check the Extinguisher for any damage in transit and also check the stamp of approval before installation.&nbsp; The seal and tamper indicators are not broken or missing.</li><li>Fire Extinguisher should be installed in designated location without obstructions.</li><li>Pressure should be readable to indicate operable pressure range and full of extinguishing media.</li></ul>&nbsp; &nbsp; &nbsp; Maintain the register for data like data of initial charging, next due date of refilling, serial number etc.<p></p><p>&nbsp;</p><p><font color="#ff0000" size="4"><b>OPERATING INSTRUCTIONS</b></font><br></p><p></p><ul><li><font size="3">Keep the extinguisher upright.</font></li><li><font size="3">Remove safety pin.</font></li><li><font size="3">Break seal only in case of fire.</font></li><li><font size="3">Keep away from heat.</font></li><li><font size="3">Do not rely partially&nbsp;used or discharges extinguisher.</font></li><li><font size="3">Check pressure gauge periodically</font></li></ul><span style="font-size:medium;">Approach as near as possible to the fire &amp; Aim at the base of fire.</span><br><p></p><p><span style="font-size:medium;"><br></span></p><p><font color="#ff0000" size="4"><b>INSPECTION INSTRUCTIONS</b></font></p><p>Fire Extinguisher shall be checked to ensure following :</p><p></p><ul><li>The seals and tamper indicators are not broken or missing.</li><li>It is full (by weighing or lifting).</li><li>It is not obviously damaged, corroded, leaking or has clogged nozzle.</li></ul>It's pressure gauge reading or indicator is in the operable range or position.<p></p><p><br></p><p><font color="#ff0000"><b><font size="4">MAINTENANCE</font></b>&nbsp;</font></p><p></p><ul><li><font color="#000000">Examine and verify that pressure gauge is working properly for indicating internal pressure of the extinguisher</font></li><li><font color="#000000">Examine extinguisher body externally. Damaged or corroded extinguisher should be replaced.</font></li></ul><span style="color:rgb(0, 0, 0);">Weigh the extinguisher to check its contents and compare it with mass recorded on the cylinder. In case of loss of more than 10 percent, the extinguisher should be sent for recharging.</span><br><p></p><p><span style="color:rgb(0, 0, 0);"><br></span></p><p><font color="#f23a3a" size="4"><b>RECHARGING&nbsp;</b></font></p><p></p><ul><li><font color="#000000">Recharge the extinguisher after any use.</font></li><li><font color="#000000">Recharge the Extinguisher as per manufacturer's recommendation.</font></li><li><font color="#000000">Replace the extinguisher with same class and at least equal rating in case of out of service.</font></li><li><font color="#000000">Recharge the extinguisher with mass as specified on the label.</font></li><li><font color="#000000">Perform leak test on Stored Pressure and self expelling types of Fire Extinguishers.</font></li></ul><p></p><p><font color="#ff0000" size="4"><b><br></b></font></p><p><font color="#ff0000" size="4"><b>WARNING&nbsp;AND CAUTION</b></font></p><p></p><ul><li><font color="#000000" size="3">Fire Extinguisher must be completely depressurized before any attempt is made to remove the valve for Maintenance, Hydro Test or Recharging</font></li><li><font color="#000000" size="3">Never has any part of your body over the extinguisher while removing the valve assembly.</font></li><li><font color="#000000" size="3">Do not puncture the extinguisher body.</font></li><li><font color="#000000" size="3">Keep the extinguisher in cool place.</font></li><li><font color="#000000" size="3">Maintenance, Servicing and recharging shall be performed by trained person.</font></li><li><font color="#000000" size="3">Stored Pressure type Fire Extinguishers shall be pressurized only to charging pressure specified on the FE nameplate.</font></li><li><font color="#000000" size="3">Do not convert Fire Extinguisher from one type to another.</font></li></ul><p></p></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 19 Nov 2019 08:52:55 +0000</pubDate></item><item><title><![CDATA[Fire Safety!]]></title><link>https://www.pranavfiresafety.com/blogs/post/Fire-Safety</link><description><![CDATA[Fire Safety! Prevention First’s educational campaign goes like: “Change Your Clock; Test Your Alarms; practice Your Home Fire Drill; Alarm Goes Off - ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_JG0vgtVmTuSyuxmQPsbLXA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_4QiDHXZHRoq4vfWk2xzKyQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_kUb4A-QBRQCnqdHnLlgt5w" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_PKnjCJcZT1-b2GPu2HwkoA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align- " data-editor="true"><div><p><span><br></span></p></div></div>
</div><div data-element-id="elm_Wl-zUZj8QuCTjwbu5Wj4og" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align- " data-editor="true"><div><p><span><a class="uiStreamPrivacy inlineBlock fbStreamPrivacy fbPrivacyAudienceIndicator _5pcq" href="https://www.facebook.com/pranaventerprise/posts/1297217070318748#"></a></span></p><div class="_5pbx userContent"><p><span>Fire Safety!<br> Prevention First’s educational campaign goes like: “Change Your Clock; Test Your Alarms; practice Your Home Fire Drill; Alarm Goes Off - You Get Out !” twice every year. Government and Non-Government Organisations keep broadcasting such warning under public interest because even the slightest ignorance can prove deadly. Fire accidents at home and work places are the most common hazards occurring which can be fatal and destructive beyond our imagination. The only good thing about hazards is that they are preventable up to an extent. If you are an employer, owner, landlord, occupier, or anyone else with control of the work or home premises then you are definitely entitled as the ‘responsible person’. You are responsible for fire safety in the home or work premises. As the saying goes ‘Accidents foreseen are half avoided’ so does your responsibility of being alert, active, spontaneous and adopting the right behaviour and procedure at the time of any fire accidents.</span></p><p><span><br></span></p><p><span>We are providing best fire extinguisher and refilling fire extinguisher product and services in Ahmedabad, Gujarat, As Pranav Enterprise.&nbsp; <br></span></p><p><span><br></span></p><p align="center"><span>&nbsp;&nbsp; <font size="4"><b>&quot; Safety has never Holiday &quot;</b></font></span><br></p></div><br><br><p></p></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 21 Mar 2017 10:33:01 +0000</pubDate></item></channel></rss>